Introduction
Weis is a specialist company with over 20 years of experience in the
commissioning, testing & maintenance of switchgear and power network
fault monitoring within the Power Utility Industry.
Based on its successful SA100 Switchgear Analyser, Weis has developed
a Reduced version (SA100 ’R’) with fewer channels providing
a lower cost robust switchgear test set for performance analysis on high,
medium and low voltage circuit breakers.
Breaker Test & Analysis software is an essential 32-bit Windows™
database program that provides an easy to use operator interface for configuring
& displaying the SA100 ’R’ test results in graphical and
text report formats.
BTA software runs on a standard IBM compatible PC with a 32-bit Windows™
operating system. This permits the transportation of test records to a
regular office based or portable computer.
The display and printing of a report can be fully customised to include
logo’s, in-house styles, text phrases and results format, thus eliminated
the need to manually complete a written form in most cases.
Possible test results which can be computed per phase for each breaker
operation include:-
- Peak Coil Current, Current Pulse Length
- Operate Times (Main / Resistive)
- Operate Time Spread (Main / Resistive)
- On Time, Dead Time
- Datum Velocity, Velocity at Contact Touch
- Stroke, Contact Length (Main / Resistive)
- Contact Separation
- Travel Overshoot, Rebound
- Mechanism Times (Pre Latch / Latch Period)
- Fingerprint Comparison on all channels (Grey Zone Checking)
Features
- ROBUST SWITCHGEAR TEST AND ANALYSIS SYSTEM FOR PORTABLE OR FACTORY
USE
- COMPUTED RESULTS WITH CUSTOM REPORT FORMAT FEATURE, REDUCING TEST
TIME
- CREATE A ELECTRONIC LIBRARY OF BREAKER TEST SETTINGS AND SIGNATURES
- REVISED CONFIGURATION / RECALCULATION ON PREVIOUS TESTS CAPABILITY
- SUBSTATION ENVIRONMENT PROVEN WITH A 12.1” HIGH-BRIGHT COLOUR
TFT DISPLAY
- INDENPENDENT CONTROL OF TRIP AND CLOSE AC OR DC COILS
- 6 ANALOGUE INPUT FOR: 1 x DUAL RANGE (5 / 30A) TRIP AND CLOSE COIL
CURRENT , 1 x TRAVEL, 3 x USER CONFIGURABLE
- 10 DIGITAL INPUTS FOR: TIMING OF UP TO 4 MAIN AND 4 RESISTIVE CONTACTS,
2 x TIMING CONTACTS (24-250V DC or 0V)
Specifications
| INPUTS |
| Analogue: |
1 x Independently controlled trip (open)
and close coil current inputs. |
|
1 x Resistive (linear or rotary) travel
transducer inputs. |
|
3 x User configurable 0 - 10V DC or 0 -
200mV DC inputs, selected via input sockets. |
|
|
| Analogue Accuracy: |
<0.5% of fullscale. |
| Digital: |
8 x Contact status inputs providing timing
of up to 4 main contacts and 4 resistive contacts (dry contacts). |
|
2 x User configurable inputs for contact
timing (24 - 250V DC). |
| Resistive Contact Range: |
15 - 10,000 ohms. |
| Digital Resolution: |
100µSec. |
| Connectors: |
4mm safety socket. |
| OUTPUTS |
|
| Coil Operation: |
Solid state outputs for trip (open) and
close. |
| Coil Peak Current: |
5 or 30A selectable via input sockets. |
| Coil Max. Voltage: |
400V peak. |
| RECORDING |
|
| Resolution: |
12 bit A/D (1:4096) and 10 kHz sampling
rate. |
| Recording Time: |
60 seconds (64Mbytes RAM). |
| Synchronisation: |
All inputs sampled simultaneously |
| Start trigger: |
Coil current or selectable on any analogue
/ digital input. |
| GENERAL SYSTEM |
|
| PS2
sockets for external keyboard with built in trackball.
12.1”
TFT SVGA (800x600) “High-Bright” colour display (350cd).
3½”
1.44Mbyte floppy disk drive and EIDE hard disk drive.
VGA
port for external screen, RS232 communications port, parallel
printer port and USB port.
Windows™
Millennium Edition. All standard Windows Centronics or USB printers
supported.
Safety keyswitch
to enable/disable coil operation. |
| REAL-TIME CLOCK |
|
| Range: |
Time, date, leap year and day of the year
with internal battery backup. 100mS resolution. |
| PROGRAMMING
- SETTABLE PARAMETERS |
| User strings: |
Site name, breaker number, breaker type,
line name, operator name and 15 user configurable. |
| Test times: |
Close, Open, Trip Free, Close-Open, Open
Close, Open-Close-Open. |
| Coil operate times: |
Initial delay, trip coil “on-time”, close
coil “on-time”, delay time between closing and opening, delay time
between opening and closing. |
| Channels: |
Analogue - Input name,
fullscale value, units. Digital - Input name. |
| Datum points: |
Velocity calculation points on travel (speed)
curve. |
| COMPUTED
RESULTS |
| Up to a sequence of 3 operations
detailing 3-phase information: Peak coil current, operate
times and operate time spread (main/resistive), on time, dead
time, datum velocity, velocity at contact touch, stroke, contact
length (main/resistive), contact separation, travel overshoot
and rebound. |
| OPERATING
VOLTAGES |
| Prime Power: |
100 to 350V DC, 88 to 264V AC auto-sensing
via IEC power connection. Burden <60 VA. |
| ENVIRONMENTAL |
| Operating
Temperature: |
-20ºC to +60ºC (-4ºF to +140ºF) |
| Humidity: |
0 to 97% RH non-condensing. |
| Isolation: |
2kV rms for 1 minute (channel to channel,
channel to earth). |
| Surge
Withstand
Transient: |
To
IEC 801-5. 1.2/50mS.
Common Mode: Severity
level class 4.
Series Mode: Severity
level class 3. |
| Fast Transient Burst: |
To IEC 801-4 level 3. |
| RFI Immunity: |
To IEC801-3 level 3. 10V/m 26-1000MHz. |
| Emissions: |
To EN50081-1: 1992. |
| MECHANICAL
DETAILS |
| Enclosure: |
6U steel enclosure suitable for Euro 19”
wide rack mounting or free standing (tabletop). |
| Ventilation: |
Fan assisted. |
| Weight: |
<9kg. |
| Optional Carry Case: |
Reinforced aluminium with wheels on one
end, 710mm(W) x 480mm(H) x 370mm(D). |
| DUE TO CONTINUING DEVELOPMENT
AND IMPROVEMENTS WEIS RESERVES THE RIGHT TO CHANGE THIS SPECIFICATION
WITHOUT NOTICE
Windows is a trademark for Microsoft Inc. |
|